Pork thawing equipment, reasons for incomplete thawing of pork
The pork thawing equipment mainly achieves the effect of meat thawing through low-temperature air circulation. If incomplete thawing occurs, the possible reasons may be as follows:
1、 Inappropriate temperature setting
The temperature inside the thawing device should be kept within a certain range, not the lower the better. Low temperatures can cause the surface of meat to freeze hard while the interior remains frozen, resulting in incomplete thawing.
2、 Time is not enough
The thawing time required for meat of different thicknesses and volumes varies, and should be adjusted according to the actual situation. The hasty thawing process may result in some areas not being fully thawed.
3、 Improper storage location of meat
In order to evenly heat and thaw all parts of the meat, it is advisable to keep the meat flat during the thawing process, avoiding overlapping or stacking together to avoid affecting the thawing effect.
4、 Unfreezing equipment malfunction
If there are problems with the equipment, such as circulation system failure or low cooling system efficiency, it can also lead to incomplete thawing.
5、 Reasons for compressor not starting
1. Check if there are any issues with the compressor's wiring; If there is a problem with the power circuit, check and restore it.
2. The starting capacitor of the compressor is damaged or burned out; Solution: Repair the capacitor or replace it directly.
3. Due to reasons such as insufficient or dirty compressor refrigeration oil. Solution: Replace the refrigeration oil of the corresponding compressor to solve the problem.
4. The reason for the compressor not starting or being protected due to a lack of refrigerant or other reasons.
Solution: Check if there are any problems with the pipelines related to the compressor. If there are any issues, repair or replace the refrigeration pipelines with new ones, and add the corresponding refrigerant.

6、 Reasons for humidifier damage or malfunction
1. Humidifier damaged
Solution: Replace the humidifier or repair damaged humidifier accessories
2. Caused by the rupture of humidifier pipeline
Solution: Replace the damaged humidifier pipe
7、 Reasons for the malfunction of the circulating fan
1. Reasons for damage or burnout of circulating fans in the warehouse
Solution: Repair or replace
We have briefly introduced the reasons why pork thawing equipment cannot completely thaw pork. In response to the above situation, we suggest that you check and adjust the working status of the thawing equipment in a timely manner, and appropriately extend the thawing time or adjust the thawing temperature. At the same time, pay attention to the placement of meat, and try to ensure that all parts of it are evenly exposed to cold air circulation. The content is for reference only, and the interpretation rights belong to Ganzhou Dachang Air Conditioning Equipment Engineering Co., Ltd. If you have any questions, please contact us!
Original link: https://www.dachangequip.com/cjwt/293.html
Note: The copyright belongs to Ganzhou Dachang Air Conditioning Equipment Engineering Co., Ltd. For commercial reprints, please contact the author for authorization. For non-commercial reprints, please indicate the source.